Ductile Iron Cement lined pipe Manufacturer
Check DI Cement lined pipe Price, Ductile iron concrete lined pipe manufacturer.
Stockholder of Heavy Duty Ductile Iron Cement Lined Pipe.

Cast Iron cement lined pipe

DI concrete lined pipe

Cast iron cement lined pipe
Tubos India is one of the large manufacturers for high quality Ductile iron cement lined pipes. Ductile Iron Cement Lined are that of ductile iron but on their inner surface, they have a cement lining. Ductile cement Line are mostly used for the distribution of water. Ductile iron Cement lined dimensions are based on the thicknesses, circumferences, diameters, as well as on the minimum thickness requirement of the standard cement lining. Ductile Iron Cement lining of steel pipes gives a protective layer to the lining of the interior of the steel pipes, this ensures that the pipes has a smooth and dense.
DI Cement Lined Pipes is considered to be ideal for continuous use at pH ranges between 6 and 12 for non-seal coated linings and for seal-coated linings the pH range should be between 4 and 12.
Ductile Iron Cement Lined thickness
Standard thickness Ductile Iron cement lining per C104 AWWA for all normal installation.
Size (in.) | Nominal Pipe Length (ft.) | Standard Thickness | Double Thickness | ||
---|---|---|---|---|---|
Weight Per Foot (lb.) | Weight Per Length (lb.) | Weight Per Foot (lb.) | Weight Per Length (lb.) | ||
4 | 18 | 0.87 | 17 | 1.71 | 31 |
6 | 20 | 1.3 | 26 | 2.57 | 51 |
8 | 20 | 1.74 | 35 | 3.45 | 69 |
10 | 20 | 2.15 | 43 | 4.28 | 86 |
12 | 20 | 2.57 | 51 | 5.12 | 102 |
14 | 20 | 4.49 | 90 | 8.93 | 179 |
16 | 20 | 5.13 | 103 | 10.19 | 204 |
18 | 20 | 5.76 | 115 | 11.47 | 229 |
20 | 20 | 6.4 | 128 | 12.73 | 255 |
24 | 20 | 7.68 | 154 | 15.31 | 306 |
30 | 20 | 12.76 | 255 | 25.42 | 508 |
36 | 20 | 15.31 | 306 | 30.51 | 610 |
42 | 20 | 17.82 | 356 | 35.53 | 711 |
48 | 20 | 20.35 | 407 | 40.6 | 812 |
54 | 20 | 22.89 | 458 | 45.68 | 914 |
60 | 20 | 24.71 | 494 | 49.32 | 986 |
64 | 20 | 26.35 | 527 | 52.61 | 1052 |
Ductile Iron cement pipe diameter
Diameters, Circumferences and Areas for Thickness Class Ductile Iron Standard Cement-Lined
Nominal Size Inches | Outside Diameter Inches | Inside Diameter Inches |
---|---|---|
3 | 3.96 | 3.33 |
4 | 4.80 | 4.15 |
6 | 6.90 | 6.27 |
8 | 9.05 | 8.38 |
10 | 11.10 | 10.39 |
12 | 13.20 | 12.45 |
14 | 15.30 | 14.45 |
16 | 17.40 | 16.53 |
18 | 19.50 | 18.61 |
20 | 21.60 | 20.69 |
24 | 25.80 | 24.85 |
30 | 32.00 | 30.97 |
36 | 38.30 | 37.19 |
42 | 44.50 | 43.31 |
48 | 50.80 | 49.53 |
54 | 57.56 | 56.17 |
Based on Ductile Iron pipe class 50 nominal thickness for all sizes, except class 51 nominal thickness for 3" and 4" – as specified in c151 awwa and on standard ductile iron cement lining minimum thickness specified in awwa c104. The value of pi(Π) used in calculation = 3.1416.
Ductile Iron cement weight
Thickness Class | Nominal Size Inches | Gallons Held (Per Foot) | Pipe (Pounds Per Foot) | Water (Pounds Per Foot) | Total (Pounds Per Foot) |
---|---|---|---|---|---|
51 | 3 | 0.45 | 10.1 | 3.8 | 13.9 |
51 | 4 | 0.70 | 12.7 | 5.9 | 18.6 |
50 | 6 | 1.60 | 18.2 | 13.4 | 31.6 |
50 | 8 | 2.86 | 25.8 | 23.9 | 49.7 |
50 | 10 | 4.40 | 33.9 | 36.7 | 70.6 |
50 | 12 | 6.32 | 43.2 | 52.7 | 95.9 |
50 | 14 | 8.51 | 55.1 | 71.1 | 126.2 |
50 | 16 | 11.14 | 64.7 | 93.0 | 157.7 |
50 | 18 | 14.12 | 74.5 | 117.9 | 192.4 |
50 | 20 | 17.45 | 84.8 | 145.7 | 230.5 |
50 | 24 | 25.17 | 106.6 | 210.1 | 316.7 |
50 | 30 | 39.10 | 139.3 | 326.4 | 465.7 |
50 | 36 | 56.38 | 182.6 | 740.7 | 653.3 |
50 | 42 | 76.46 | 229.8 | 638.3 | 868.1 |
50 | 48 | 100.00 | 828.7 | 834.8 | 1117.5 |
50 | 54 | 128.61 | 351.1 | 1056.2 | 1407.3 |
These weights are based on minimum classes (thickness for 3" and 4" class 51 and for 6" through 54" class 50) ductile iron with minimum thickness standard cement lining as specified in c104 awwa and on weight of water of 62.4 Pounds per cubic foot.
Ductile Iron Cement Lined Mechanical Properties
Standard | Product | Nominal Diameter DN mm | Tensile strength N/mm2 | Yield strength N/mm2 | Elongation % | Hardness HB |
ISO2531 EN545:2010 EN598:2009 | Ductile iron pipes | DN100~1000mm | ≥420 | ≥300 | 10 | ≤230 |
DN1100~2600mm | ≥300 | 7 |